Controlled by processor ( 9 )
•
Inputs from:
•Operator
• EDC control pod ( 8 )
• EDC control panel ( 2 )
• Linkage
• Lift arm potentiometer ( 7 )
• Load sensing pins ( 6 )
• Radar ( for slip control only ) ( 1 )
•
Outputs
• EDC valve ( 4 ) - controls CCLS pump via
sensing lines and diverts pressure oil to lift cylinders.
• Instrument cluster ( 3 ) - displays
linkage height, slip % and EDC errors.
•
•
Controls position of implement and / or regulates draft force on tractor by
raising / lowering implement into / out of work